Aplikacja

  • Pipe with 0.1 m diameter
  • Full filled
  • Low water volumes of approx. 3 l/s

Zdefiniowanie problemów

  • Detection of low issue quantities from a drinking water overhead tank during nighttimes
  • Replaces the EMF not working properly due to low flow velocities
  • Data transmission via GPRS to center
Nighttime Supply Flow Measurement
Installation principle of V-measurement
Nighttime Supply Flow Measurement

Rozwiązania

  • The flow measurement system Type NivuSonic has been used.
  • The measurement has been installed as v-shaped single path measurement due to the narrow diameter.
  • Using the transmitter-integrated GPRS modem allows direct connection to a process control system.

Korzyści

  • Easy, straightforward and quick upgrading
  • No additional adapters and constrictions required
  • High accuracy and reliability at low flow velocities

Wykorzystane produkty

Nie znalazłeś odpowiedniej aplikacji

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Applications & Solutions

Applications & Solutions Our Applications and Solutions catalogue offers a brief overview to the most interesting application examples in a single pdf-document.

Szanowni Państwo,

W związku ze zmianą witryny naszej strony część informacji nadal widnieje w języku angielskim. Nasz personel pracuje nad wprowadzeniem nowych korekt w języku polskim. Z góry przepraszamy za utrudnienia.

W przypadku pytań na temat produktów lub usług prosimy o kontakt z naszym biurem lub odpowiednim personelem: Kontakt

Z wyrazami szacunku zespół firmy NIVUS.

X