Aplikacje

Oczyszczalnie ścieków - Opróżnianie zbiorników (PL)

Pomiar przepływu na odpływach (PL)

Kläranlagen
Flow Measurement Using Inverted “Goose Neck” Siphon
Installed measurement
Flow Measurement Using Inverted “Goose Neck” Siphon

Aplikacja

  • Pipe DN 150, made of stainless steel
  • Full filled
  • EMF, faultily installed

Zdefiniowanie problemów

  • Accurate measurement with high operational reliability required, which currently cannot be guaranteed due to the installed EMF, air within the pipeline and a much too short calming section
  • Quick, easy and cost-efficient retrofitting
Flow Measurement Using Inverted “Goose Neck” Siphon
Measurement Setup
Flow Measurement Using Inverted “Goose Neck” Siphon

Rozwiązania

  • A transit time measurement system Type NivuSonic using 2 measurement paths has been used.
  • The sensors have been installed in a measuring pipe with integrated ball valves. This allows to replace sensors under process conditions at any time.
  • Crosswise path arrangement virtually eliminates crossflow during calculation.

Korzyści

  • Easy and robust installation using calibrated pipe segment
  • No bypass required
  • High accuracy and reproducibility

Nie znalazłeś odpowiedniej aplikacji

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Applications & Solutions

Applications & Solutions Our Applications and Solutions catalogue offers a brief overview to the most interesting application examples in a single pdf-document.

Szanowni Państwo,

W związku ze zmianą witryny naszej strony część informacji nadal widnieje w języku angielskim. Nasz personel pracuje nad wprowadzeniem nowych korekt w języku polskim. Z góry przepraszamy za utrudnienia.

W przypadku pytań na temat produktów lub usług prosimy o kontakt z naszym biurem lub odpowiednim personelem: Kontakt

Z wyrazami szacunku zespół firmy NIVUS.

X